CapitalKnowledge

Projects and Designs > Running Design Rule Checks > Design Rule Check Descriptions for Capital Systems Modeler

Capital Systems Modeler

  • Naming DRCs

There are particular design rule checks related to naming that you can run for a Capital Systems Modeler design.

Duplicate

Names for Shared Objects in Project

Identifies shared objects having a name that is identical to that of another shared object of the same kind in the project but having different option expressions. The default status for this check is true, and its default severity setting is error. The check works in conjunction with the Uniqueness project preference.

Messages Variables
{0} have duplicate names. {0} - Shared Objects (of same kind) having same name on the design (Function, Message, Signal)

Duplicate

Names in Design

Identifies objects having a name that is identical to that of another object of the same kind on the same design or a shared object of the same kind but having different option expressions. The default status for this check is true, and its default severity setting is error. The check works in conjunction with the Uniqueness project preference.

Messages Variables
{0} have duplicate names. {0} - Objects (of same kind) having same name on the design (Block, Function, Highway, Message, Port, Signal)

Invalid

name for component

Identifies objects with names that do not appear in the list of valid names for the project's object type.

Messages Variables
Invalid name: {0} is not on the list of valid {1} names {0} - Function Object {1} - Function Object type

Invalid

name for shared object

Identifies, within the selected design, shared objects with names that do not appear in the list of valid names for that project’s shared object type.

Messages Variables
Invalid name: {0} is not in the list of valid shared {1} names {0} - Signal or message name {1} - Shared object type (signal or message)

Invalid

short description

Identifies any object for which the short description has been changed in the object type information in Capital Project Manager but this change has not been applied in Capital Systems Modeler.

Messages Variables
The short description of {1} {0} is invalid {1} - Short-described object type (Block, Function, Function Build list, Function Design, Function Diagram, Highway, Message, Port, Signal) {0} - Short-described object (Block, Function, Function Build list, Function Design, Function Diagram, Highway, Message, Port, Signal) name
The short description of object {0} is invalid {0} - Short-described object (Block, Function, Function Build list, Function Design, Function Diagram, Highway, Message, Port, Signal) name

Parent Topic:

Design Rule Check Descriptions for Capital Systems Modeler