CapitalKnowledge

Reports > Generating Reports > Available Reports

Custom Logic Wire List

You can select this option to display a list of check boxes to customize the wire list report.

For each wire, you can select the following check boxes to display the attributes and properties on the report:

Attributes

or Properties of Wire

  • Name The name assigned to the wire in Capital Logic Designer.

  • Description Descriptive text entered into the Description field of the design.

  • Short Description Short description entered against the design.

  • Wire CSA The cross-sectional area of the wire.

  • Wire Length The length of the wire.

  • Wire Specification The wire specification.

  • Architectural Cost The architectural cost of the wire.

  • Assembly The assembly the wire is part of.

  • Customer Name The unique name used to identify the component to the customer.

  • Customer Part Number The unique number used to identify the component to the customer.

  • Default Name The default name of the wire within the selected design.

  • Design The name of the design.

  • Design Abstraction The abstractions assigned to the design.

  • Generated Name The generated name of the wire on the diagram.

  • Harness The name of the harness in which the wires exist.

  • Included On BOM Indicates if the wire is included on the bill of materials.

  • Included On Cut Chart Indicates if the wire is included on the cut chart.

  • Length Change Type Specifies the Length Change Type applied to the wire: Neither, Absolute, or Offset.

  • Length Change Value Specifies a value used to override the calculated wire length, based on the Length Change Type.

  • MCAD ID If the harness was bridged in from an MCAD application, this field displays the component's unique identifier as derived from the external data.

  • Modified Length The modified length of the wire.

  • Multicore The name of any multicore to which the wire belongs.

  • Name Overridden The previous name of the wire if it has been overridden.

  • Option Expression The options applied to the wire.

  • Outside Diameter Specifies the outside diameter of the wire.

  • Part Number The part number of any library part associated with the wire.

  • Poke Home Indicates if the wire is poke home wire, connected during installation.

  • Revision The design revision.

  • Status The release status of the design.

  • Supplier Name The name of the supplier from which the component is sourced.

  • Supplier Part Number The number used by your supplier to identify the component.

  • Terminal Material Code The terminal material code applied to the end of the wire.

  • Type Code The component type, as defined within the library.

  • Unmodified Length The unmodified length of the wire.

  • Wire Color The color of the wire.

  • Weight The total weight of the harness.

  • Wire Material The material from which the wire is manufactured.

  • Wire Note Any additional information recorded against this wire.

  • Attributes Lists the attributes of the wire applicable for the Capital Logic Designer design, together with a text box to specify your required attribute. You can enter more than one attribute using a semi-colon separated list.

  • Properties Lists the properties of the wire applicable for the Capital Logic Designer design, together with a text box to specify your required property. You can enter more than one property using a semi-colon separated list.

  • Reset Resets all attributes and properties to their previous state prior to starting modifications.

  • Clear Clears all attributes and properties.

From

Wire End Attributes

  • From Component Name Lists the component name applicable for the start of a wire in Capital Logic Designer Designs.

  • From Component Option Lists the component option applicable for the start of a wire in Capital Logic Designer Designs.

  • From Connector Name Lists the connector name applicable for the start of a wire in Capital Logic Designer Designs.

  • From Harness Connector Part Number Lists the harness connector part number applicable for the start of a wire in Capital Logic Designer Designs.

  • From Pin Name Lists the pin name details applicable for the start of a wire in Capital Logic Designer Designs.

  • From Pin Option Lists the pin option details applicable for the start of a wire in Capital Logic Designer Designs.

  • From Mated Pin Name Lists the mated pin name details applicable for the start of a wire in Capital Logic Designer Designs.

  • From Mated Pin Option Lists the mated pin option details applicable for the start of a wire in Capital Logic Designer Designs.

To

Wire End Attributes

  • To Component Name Lists the component name applicable for the end of a wire in Capital Logic Designer Designs.

  • To Component Option Lists the component option applicable for the end of a wire in Capital Logic Designer Designs.

  • To Connector Name Lists the connector name applicable for the end of a wire in Capital Logic Designer Designs.

  • To Harness Connector Part Number Lists the harness connector part number applicable for the end of a wire in Capital Logic Designer Designs.

  • To Pin Name Lists the pin name details applicable for the end of a wire in Capital Logic Designer Designs.

  • To Pin Option Lists the pin option details applicable for the end of a wire in Capital Logic Designer Designs.

  • To Mated Pin Name Lists the mated pin name details applicable for the end of a wire in Capital Logic Designer Designs.

  • To Mated Pin Option Lists the mated pin option details applicable for the end of a wire in Capital Logic Designer Designs.

From

Wire End Properties

  • From Component Properties Lists the component properties as entered in the text box for the start of a wire in Capital Logic Designer Designs.

  • From Connector Properties Lists the connector properties as entered in the text box for the start of a wire in Capital Logic Designer Designs.

  • From Pin Properties Lists the pin properties as entered in the text box for the start of a wire in Capital Logic Designer Designs.

  • From Mated Pin Properties Lists the mated pin properties as entered in the text box for the start of a wire in Capital Logic Designer Designs.

To

Wire End Properties

  • To Component Properties Lists the component properties as entered in the text box for the end of a wire in Capital Logic Designer Designs.

  • To Connector Properties Lists the connector properties as entered in the text box for the end of a wire in Capital Logic Designer Designs.

  • To Pin Properties Lists the pin properties as entered in the text box for the end of a wire in Capital Logic Designer Designs.

  • To Mated Pin Properties Lists the mated pin properties as entered in the text box for the end of a wire in Capital Logic Designer Designs.

  • Next Click the Next button to confirm your selections and generate the report.

Parent Topic:

Available Reports

Capital Logic Designer User Guide, 2512

Unpublished work. © 2025 Siemens

Source: https://docs.sw.siemens.com/en-US/doc/861057055/202410078.capital_ld_user/ida36ac396-dc0e-4e52-a478-b909d99496c2 · retrieved 2026-07-18