To access: Double‑click Development projects, select the required project, and then double‑click Cable Routes > Reports > Print Pull Sheet.

Used by System Administrators to specify search criteria to find cables and print a revision‑controlled report as part of the cable route release from design to production.

This video demonstrates the tasks to select cables and print a Pull Sheet report.

Figure 28: Default Pull Sheet Report Settings

Objects

Field Description
Parameter Set Name Specify a unique name for a new parameter set or double‑click to select an existing parameter set from the Saved Parameter Sets list.
Save Set Click to create a new parameter set or save the current filter condition values to an existing parameter set.
Delete Set Click to delete the open parameter set. The set will be unavailable to select in the Saved Parameter Sets list.
Clear Fields Click to restore the fields to the default values.
Exit Click to close the Print Pull Sheet Form without saving your changes.
Vessel Specify the build / vessel number in the project containing the cable routes to print.
Cable ID Double-click the field to select a filter condition to search by Cable ID. Wildcards are permitted.
System Double-click the field to select a filter condition to search by System code and identify groups of cables in a functional unit or discipline within a project. Wildcards are permitted.
Cable Type Double-click the field to select a filter condition to search by Cable type. Wildcards are permitted.
Device Double-click the field to select a filter condition to search by Device ID. Wildcards are permitted.
Segregation Double-click the field to select a filter condition to search by Segregation code. Wildcards are permitted.
Work Package Double-click the field to select a Work Package type to identify groups of cables associated with specific installation tasks.
Hierarchy Levels Enabled only if Allow Area Hierarchy is selected on the General Tab. Click the dropdown list and select the required area hierarchy level to search: Area Floor Room Zone Double-click the field to select a code to search by. Wildcards are permitted but no partial wildcards.
Search Options Choose the search option to identify cables with either end or both ends in the hierarchy level: Cable starts or ends in the area (default) Cables contained within the area
Route Options Enabled only if Allow Point Segments is selected on the Network Tab. Select to display the route as Nodes or Segments as specified on the Display Route As project preference on the Reports Tab.
Report Options Select to provide additional instruction on the scope of any data included in the report, and the impact production of the report may have on the data: Check Print — Prints the report without impacting the status of any underlying data. Cables have the same status requirement as the For Use option. Pre-Release — Similar to the Check Print option but without the restriction on release status of the affected cables. Part-routed and unapproved cables may also be printed depending on the “Pre-release Pull Sheet Minimum Route Status” values specified on the General tab. For Use — Produced in combination with any update to underlying data, for example, raising the Route or Termination status. Note The data update is not contingent on the success of the physical or digital print. If the output fails, the data will have been updated. You can use the RePrint option to reproduce the failed output. RePrint — Used to reprint the data stored by the For Use report. You can reprint any previous revision of the document.
RePrint Revision Enabled only if the RePrint report option is selected. Select to print the latest or a specific revision of the report.
Incl. Cancelled Select Yes or No to include cancelled cables in the report.
Find Cables Click to open the Item Selection Form and display the cables in the project matching the filter conditions. You can select one or more cables to include in the report and then click Run Report.

Usage Notes

In addition to the specified filter conditions, the following options and status of the cables must be valid to display cables on a Pull Sheet report.

Field Description
Check Print Cable is not Cancelled. Cable is not set to Stop Work. Cable route status is DRCAR (Design Route Complete, Approved, Released). System (Cable / From Device / To Device) and Area (From Device / To Device) have a value other than *. If the Use Cutting Schedule project preference is cleared, the Cable Type must match the specified Spool Cable Type and the Design Length must not exceed the Cut Length. Cable has been cut and Spool cut has been recorded is selected on the “Extra Pull Sheet cable restrictions” project preference on the General tab. Cable has a spool assigned and Spool has been assigned is selected on the “Extra Pull Sheet cable restrictions” project preference on the General tab.
Pre Release Cable is not Cancelled. Cable is not set to Stop Work. System (Cable / From Device / To Device) and Area (From Device / To Device) have a value other than *. Cable route status is at or above the “Pre-release Pull Sheet Minimum Route Status” specified on the General tab but not yet released DRCAR (Design Route Complete, Approved, Released).
For Use Cable is not Cancelled. Cable is not set to Stop Work. Cable route status is DRCAR (Design Route Complete, Approved, Released). System (Cable / From Device / To Device) and Area (From Device / To Device) have a value other than *. If the “Use Cutting Schedule” project preference is cleared, the Cable Type must match the specified Spool Cable Type and the Design Length must not exceed the Cut Length. Cable From or To Device is not Cancelled. Cable has been cut and Spool cut has been recorded is selected on the “Extra Pull Sheet cable restrictions” project preference on the General tab. Cable has a spool assigned and Spool has been assigned is selected on the “Extra Pull Sheet cable restrictions” project preference on the General tab.
RePrint Cable is not Cancelled. The Incl. Cancelled option value is No. At least one For Use revision exists.