Wiring > Combined Signals and Combined Wires
Uncombining All Child Signals from a Combined Signal
You can uncombine a combined signal and split out all of its child signals so that the combined signal no longer exists and the child signals use separate wires.
Procedure
In the Design Browser (Design tab), right-click the combined signal and choose Uncombine.
Results
The child signals are moved from under the combined signal and the combined signal is removed from the Design Browser (Design tab).
Any combined wires that belong to the combined signal are split and are added to all of the split child signals.
Parent Topic:
Combined Signals and Combined Wires
Related Topics
Combined Signals and Combined Wires
Creating a New Combined Signal from Selected Signals
Adding Selected Signals to an Existing Combined Signal
Combining Selected Signals with a Compatible Signal
Removing Selected Child Signals from a Combined Signal
Creating a New Combined Wire from Selected Wires
Creating a New Combined Wire from a Selected Set of Wires for a Combined Signal
Adding Selected Wires to an Existing Combined Wire
Combining Selected Wires with a Compatible Wire
Uncombining Wires
Capital Systems Integrator User Guide, 2512.2606
Unpublished work. © 2026 Siemens