New Symbol Instance for Additional Pins when Using a Prototype
Symptom: When creating a design using a prototype containing symbols, Capital Schematic Generator for Systems Integrator generates a new symbol instance for newly required pins.
Solution
When Capital Schematic Generator for Systems Integrator creates a wiring diagram, if it uses a prototype containing symbols and those symbol instances have insufficient pins for the newly synthesized wiring, then a new symbol instance is created for the additional pins.
Capital Schematic Generator for Systems Integrator does not add additional pins to symbol instances already existing in a prototype diagram.
You can prevent the creation of a new symbol instance by adding the required pins to the prototype wiring diagram prior to running Capital Schematic Generator for Systems Integrator.