Capital Formboard Designer > Fixture Placement and Deletion Constraints
Fixture Placement Segment
at Intervals
You can configure this constraint to automatically place fixtures on bundles using predefined spacing.
Usage
Place Fixture on All Segments for All bundles matching Name = .* and
Arguments
All Segments
Use this argument to set the scope of bundle segments considered by constraint. All segments The constraint considers all segments of a bundle from the “from” argument.
Single segment The constraint considers the first available segment from the “from” argument. Note If the specified “offset” is greater than the length of the first single segment, the constraint places the fixture at the specified offset on the next segment.
All Bundles
See All bundles.
matching
See matching.
min length
See min length.
max length
See max length.
at intervals
See at intervals.
with part number
See part number.
position
See position.
from
See from.
offset
See offset.
using datum
See using datum.
Examples
This example shows the constraint placing a fixture on a “Single segment” at a “30.0” unit “offset” from a “Connector”. The interval is set to “0.0” which means only one fixture is placed per bundle. Figure 327: Single Segment Usage
This example shows the constraint placing multiple fixtures on “All segments” starting from a “30.0” unit “offset” from a “Connector” then at “50.0” unit intervals. Figure 328: All Segment Usage
Parent Topic:
Fixture Placement and Deletion Constraints
Related Topics
Fixture Placement Segment at Midpoint
Fixture Placement Segment at Midpoint in Pairs
Fixture Placement Segment at Offset
Fixture Placement Segment in Pairs at Offset
Fixture Placement Arc at Intervals
Fixture Placement Arc at Midpoint
Fixture Placement Arc at Offset
Fixture Placement Bundle Junction
Fixture Placement Component
Fixture Placement Elbow
Fixture Placement Nodes
Automatic Fixture Part Number Selection
Automatic Part Number Selection Rules
Placing Fixtures Automatically
Capital Harness Designer User Guide, 2512
Unpublished work. © 2025 Siemens
Source: https://docs.sw.siemens.com/en-US/doc/861057055/202410078.capital_hd_user/idb7cd392b-0d21-4ad4-a0ea-5d23e6a4b241 · retrieved 2026-07-18