CapitalKnowledge

Capital Configuration Optimizer - Harness Level Optimization > Harness Level Optimization Tool Concepts > Full Complexity

Manually Generating the Full Complexity Harness Levels for a Harness

You can create (generate) the full complexity harness levels for a harness to see how many harness levels it has with no giveaway. Metrics show you the cost of that harness.

Prerequisites

  • You must have entered basic product plan data.

  • In Capital Logic Designer, you must have created the connectivity schematics for the project and have specified option expressions for design objects.

  • In Capital Systems Integrator, you must have created the topology design for the project and have specified option expressions for design objects.

  • Modular Wiring Synthesis must have been run on the topology design.

Procedure

  1. With a Capital Systems Integrator diagram open, press Space Bar and enter Harness Level optimization, or right-click a harness in the Design Browser (Design Tab) and choose Optimize Harness; the Harness Level Optimization Dialog Box displays.

  2. Use the Metrics drop-down list to select the type of metrics that you want to apply to the harnesses.

  3. Select the harness in the Harness table and click the Calculate full complexity for selected harnesses () button.

Results

  • The Full Levels column displays how many Harness Levels this harness has if there is no Giveaway.

  • The Full column displays the cost of the harness based on the metric selected in the Metrics drop-down if there is no giveaway.

Parent Topic:

Full Complexity

Related Topics

  • Full Complexity

  • Validating Physical Harness Levels against Full Complexity Harness Levels

Capital Systems Integrator User Guide, 2512.2606

Unpublished work. © 2026 Siemens