CapitalKnowledge

Devices

Handling of Ground Device Combinations in Wiring Synthesis

The ‘Generate separate ground wiring for each combination structure’ project preference enables intelligent ground wiring synthesis that respects partial ground device combinations across variant configurations. When enabled (the default), it prevents unwanted wiring reuse between combined and non-combined ground devices. If disabled, the system reuses wiring regardless of ground combination status.

Ground devices can be placed in multiple slots (for example, left-hand drive versus right-hand drive configurations) with different combination patterns.

In this example, you have a configuration with two ground slots (GND_DOOR_LHD and GND_DOOR_RHD).

  • GND_DOOR_LHD Slot

      This contains 3 variantly placed ground devices (GND_DOOR_ECU, GND-CTSY,
        GND-DRLK_DR), which are all combined under one combined ground device GND DOOR ECU_C.
    
      Figure 34: GND_DOOR_LHD Slot
        
        
      
    
      Regardless of the setting for the project preference, wiring synthesis reuses wiring for
        all 3 child ground devices and generates one splice with 4 wires.
    
      Figure 35: GND_DOOR_LHD Wiring Regardless of Project Preference Setting
    
  • GND_DOOR_RHD Slot

      This also contains 3 variantly placed ground devices, but only two
        devices (GND_DOOR_ECU, GND-CTSY) are combined under a combined ground device GND DOOR
        ECU_C1; GND-DRLK_DR remains separate.
    
      Figure 36: GND_DOOR_RHD Slot
        
        
      
    
      When the project preference is enabled, wiring synthesis does not reuse
        wiring for the non-combined GND-DRLK_DR. It generates one splice with 3 wires for the
        combined ground devices GND_DOOR_ECU and GND-CTSY. It also generates a separate wire for
        GND-DRLK_DR.
    
      Figure 37: GND_DOOR_RHD Wiring - Preference Enabled
        
        
      
    
      When the project preference is disabled, wiring synthesis reuses wiring for all 3 ground
        devices, even though GND-DRLK_DR is not combined with the others. This results in one
        splice with 4 wires, like the LHD configuration.
    
      Figure 38: GND_DOOR_RHD Wiring - Preference Disabled
    

Parent Topic:

Devices

Related Topics

  • Project Preferences for Capital Systems Integrator Designs

Capital Systems Integrator User Guide, 2512.2606

Unpublished work. © 2026 Siemens

Source: https://docs.sw.siemens.com/en-US/doc/861057055/202511026.capital_si_user/dmb5744329110466 · retrieved 2026-07-18