CapitalKnowledge

Capital Wiring Integrator > Capital Wiring Integrator Dialog Box and Field Reference

Edit Properties: Slot

Connector Dialog Box

To access: Select the slot to edit, press the space bar and enter Properties, right‑click and select Properties, or double‑click the slot connector in the Diagram window.

Used to edit the properties of a slot connector.

Objects

Field Description
General Tab
Name A unique label to identify the slot connector, which defaults to P appended with an incrementing number. Enter a new name or click the ellipsis button (...) to select from a list of pre-specified slot names maintained in the project’s Object Type Information in Capital Project Manager. The contents of this field are displayed in red if they are not unique within the current project. Select the Visible option to display the name next to the slot connector on the topology diagram. Click to display the Edit Name Text Attributes Dialog Box to specify how the name is displayed on the diagram. Mandatory.
Short Description Enter a line of descriptive text to provide more information about the slot connector. Select the Visible option to display the short description next to the slot connector on the topology diagram. Click to display the Edit Name Text Attributes Dialog Box to specify how the short description is displayed on the diagram. Optional.
Properties To add a property to the slot connector, click the New button, enter a Property Name in the New Property Dialog Box, and then click OK. The new property is added to the list. A property consists of the following fields: Name A unique identifier for the property. Read-only. Value The value assigned to the property. Optional. Type The data type of the value. Mandatory. If you enter a Value that is not supported by the selected Type, the Value is displayed in red text and the OK button is unavailable. The following types are available: String A mix of letters, numbers, or special characters. Integer A whole number. Float A number including a decimal (floating) point. To delete a property from the list, select it and click the Delete button, and then click OK to confirm the deletion. Optional.
Attributes Specify the values for slot connector attributes in the Value column. Select the Visible option to display the attribute value next to the slot connector on the topology diagram. Click to display the Edit Graphical Attributes Dialog Box to specify how the value is displayed on the diagram. Mandatory.
Library Part Specifies whether a library part is associated with the slot connector. Click Add to associate a library part using the Part Selection Dialog Box. Click Update to update the library part information if changes have been to the part in Capital Component Manager. Click Remove to cancel the association of the library part. Click View to display the Details Dialog Box for the library part. Optional.
Graphical Tab Specify how you want the slot graphic to appear on the topology diagram.
Primary Color Specify the color of the lines of the slot. Select the color from the dropdown list; it is previewed in the window to the right of the field. As well as color names, the list contains the following options: Default The default color used for the object by the system. Background The same color used for the background of the diagram. The color changes when the background color is toggled. Foreground If the diagram background is white, the object is black, and vice versa. Manual The Choose Object Color dialog box is displayed to select a color. Mandatory.
Thickness Specify the thickness of the lines of the graphical shape. Mandatory. Click the dropdown list and choose Default or Override to use a different thickness, and then choose the type of thickness from the second dropdown list that is displayed: Logical These thicknesses do not have a physical unit of measurement. They provide a logical progression of thickness with a default of 1. A line with thickness 2 is displayed twice as thick as a line with thickness 1, and so on. When you zoom in or out of a diagram, the line thickness does not appear any different. You select the thickness from the middle dropdown list. Physical (unit of measurement) The physical unit of measurement that has been specified as the Unit in the style set applied to the diagram. The line thickness is displayed in relation to the grid size of a diagram. When you zoom in or out of a diagram, the line grows or shrinks to stay in scale with the grid. When you select a unit, the middle dropdown list changes to a free text field where you specify the thickness. The value can be any floating-point number up to three decimal places. See “Physical Line Thickness” in the Capital Design Tools - Common Functions User Guide for a definition and links to related task flows.
Line Style Specify the style of the lines of the slot. Mandatory. Click the dropdown list and choose Default or Override to use a different style, and then choose the style from the second dropdown list that is displayed.
Rules Tab
Show Inherited Specifies what is displayed in the Object Rule Rule Contents window. Select to display all constraints that apply to the slot connector, including constraints that have been set for the whole diagram and constraints included in rules that have been added to the slot connector. Note that you cannot edit the constraints when this option is selected. Clear to display only the rules added to the slot connector and constraints that have been set specifically for the slot connector. Mandatory.
Object Rule Rule Contents Window Displays the Constraints (Capital Wiring Integrator) that apply to the slot connector. Optional. If Show Inherited is selected, you cannot edit any of the constraints. If Show Inherited is cleared, you can edit the individual constraints added to the slot connector but not the rules. A rule is indicated by and you can click the description to display the constraints in that rule (Read‑Only mode). A constraint is indicated by . Red text indicates a value that must be edited or is invalid. Green text indicates editable text.
Add Rule Ref Displays the Rule Selection dialog box to select a rule to apply to the slot connector. The selected rule is added to the Object Rule Rule Contents: window. Optional.
Add Constraint Displays the Constraint Selection dialog box to select a constraint to add to the slot connector. The selected constraint is added to the Object Rule Rule Contents window to edit it. Optional.
Routes Tab Used to specify: the route code for the connector. If there are multiple harnesses entering the connector, you can specify a different route code for the connector on each harness. whether bundles entering the connector are poke home bundles.
Harness The name of the harness entering the connector. Read-only.
Connector The name of the connector. Read-only.
Bundle The name of the harness bundle entering the connector. Read-only.
Route Code The route code used to distinguish between connectors, for example, when there is more than one slot connector combined with a slot. It is not used in Capital Wiring Integrator but it is used in Capital Harness Designer. If no route codes have been defined for the library part or no library part is assigned, you can manually specify a route code for the connector when on the harness specified in this row. Optional. If route codes have been defined for the library part used for the connector, this field is not editable and displays the appropriate code from the library part. Read-only.
Poke Home Whether the bundle specified in this row is a poke home bundle (selected) or not (cleared). Mandatory.

Parent Topic:

Capital Wiring Integrator Dialog Box and Field Reference

Related Topics

  • Editing a Slot Connector

  • Specifying a Route Code for a Slot Connector

  • Specifying a Bundle (Harness) as a Poke Home

Capital Logic Designer User Guide, 2512

Unpublished work. © 2025 Siemens

Source: https://docs.sw.siemens.com/en-US/doc/861057055/202410078.capital_ld_user/id44f8a999-6437-4969-9fde-ec0c2b9b1ba6 · retrieved 2026-07-18