CapitalKnowledge

Capital Formboard Designer > Fixture Placement and Deletion Constraints

Fixture Placement Component

You can configure this constraint to place a fixture at a specified component type.

Usage

Place Fixture with part number Part Number on Connector matching Name = .* and using datum

Arguments

Part Number

See part number.

Component (default display is Connector)

Use to specify the component type at which the fixture is placed. You can also use it to place fixtures relative to the nodes occupied by insulations, for example spot tapes and insulation run ends. Click to display a popup menu to choose from the possible values: Clip

Connector

Device

Grommet

Insulation Run End

Multi-Location Component Primary Node

Other Component

Ring Terminal

Splice

Spot Tape

matching

See matching.

using datum

See using datum.