Troubleshooting
Pre Validation Error During Harness Synchronization
During harness synchronization, the system displays a warning message that synchronization has not completed because of pre validation errors.
Causes
Pre validation errors can be:
- A library part assigned on pin lists (connectors, splices), wires, and multicores does not exist in the component library. There are two scenarios in which this can occur: When you used constraint to add a part number but the part number does not exist in the library.
When you imported a design from another database and the part number does not exist in the target database.
Pin list cavity names do not match with an assigned library part and the number of cavities exceed the number of cavities specified against the part number.
A ring terminal part number does not have only one cavity.
A multicore structure does not match with an assigned library part innercore definition.
Solution
Create a new revision of the design.