Capital Systems Integrator Dialog Box and Field Reference > Capital Schematic Generator for Systems Integrator Dialog Box and Field Reference > Generate Wiring Diagram Dialog Box > Generate Wiring Diagram Dialog Box - Design Tab
Design Details (without Generate Single Diagram Selected)
To access: Right-click on a platform design in the Project Browser Window and choose Generate Wiring Diagram. The Design Details section is displayed on the Design tab of the Generate Wiring Diagram Dialog Box.
Use this section to specify details for the logical designs generated by the current run of Capital Schematic Generator for Systems Integrator when the Generate Single Diagram field on the Design tab is not selected.
Objects
| Field | Description |
|---|---|
| Design Name | A label to identify each wiring design. Enter prefix and suffix text to create design names based on the Capital Logic Designer names. |
| Revision | Specifies the version of the designs, allowing multiple updated versions of the same designs to exist in the database. Enter prefix and suffix text to create the revisions of the generated designs based on the revisions of the matching Capital Logic Designer designs. You can leave both fields blank. |
| Short Description | Specifies a line of descriptive text to provide more information about the designs. This information displays alongside the design name and revision in the Project Browser Window. Enter prefix and suffix text to create short descriptions for the generated designs based on the short descriptions of the matching Capital Logic Designer designs. You can leave both fields blank. |
| Release Level | Use this field to record the progress of the designs through the stages of the design life cycle. A number of system-defined release levels are available, but it is possible to create custom levels in Capital Project Manager (see the Create a Project's Release Levels topic in the Capital Project Manager User Guide for more information). Regardless of the number of custom levels available, custom levels must correspond to one of the system-defined release levels: If no custom levels are configured, the only option available is Draft, which is selected by default. Any custom levels configured must correspond to the Draft system-defined level, so select the custom level required as dictated by your internal procedures. In either case, this field is mandatory. |
| Abstraction | If you are using design abstractions, select the abstraction to which the designs belong, from the dropdown list. Maintained in Capital Project Manager, abstractions allow you to group related harnesses together for reporting purposes, providing a view of a subset of a vehicle's wiring. See the Create a Project's Design Abstractions topic in the Capital Project Manager User Guide for more information. |
| Style Set | By default, Capital Schematic Generator for Systems Integrator uses the Default style set for Capital Logic Designer to style objects in the generated diagrams. If you have a license to use Capital Styling, you can use the dropdown list to select a different style set if they are available. |
| Parent Folder | Specify the parent folder (within the project structure) that contains the generated diagrams. Click the ellipsis (...) to display the Parent Folder Selection Dialog Box where you select the folder. |
| Folder Name | Displayed only if you have selected Generate Functionally Partitioned Diagrams and have not selected Generate Single Design. Enter the name of the new folder which is added below the parent folder (within the project structure) and contains the generated diagrams. The Folder Name must be unique within the Parent Folder. |
Parent Topic:
Generate Wiring Diagram Dialog Box - Design Tab
Capital Systems Integrator User Guide, 2512.2606
Unpublished work. © 2026 Siemens
Source: https://docs.sw.siemens.com/en-US/doc/861057055/202511026.capital_si_user/krx1739290831367 · retrieved 2026-07-18