To access: Click the ellipsis (...) in the Tube Selection Order column in the Harness Engineering section of the Project Preferences Dialog Box.

Used to set the order in which logic will be applied by the Tube Selection process when selecting tubes during Engineering Calculations. This applies if the system is unable to match a tube with the exact length required.

Objects

Field Description
CutShorter The system chooses a shorter or exact length tube which matches the Standard Selection Criteria and whose unit of measure is Each, Per Roll/Reel components will not be able to be selected for CutShorter.
CutExact The system chooses an exact match length tube which matches the Standard Selection Criteria and whose unit of measure is Each, Per Roll/Reel components will not be able to be selected for CutExact.
FromReel The system chooses a tube component which matches the Standard Selection Criteria and whose unit of measure is Per Roll/Reel, Each components that match exact length will not be able to be selected for FromReel.