Capital Cable Router > Routing Rules
Routing Rules Overview
You can specify routing rules to individual cables to define limitations on nodes, segments, zones, and other cables to restrict routes or force cables along a particular route.
| Criteria | Behavior |
|---|---|
| Required or prohibited segments / nodes | The cable may not visit any node or segment identified as “prohibited”. |
| Cables with hot codes | Where the segment traverses a zone associated with a hot code, the cable type must itself have a hot code value greater than or equal to the hot code value of the zone. |
| Cables that are grouped | Specifies which cables to bundle together when routed. |
| Cables that break segregation spacing rules | Specifies the segregation spacing rule between any cables. |
| Cables that break bend radius rules | The cable type minimum bend radius must be greater than the inner radius of the segment. |
| Cables that break minimum / maximum length rules | Any cable that breaks the maximum or minimum length defined. |
System Administrators can define one or multiple routing rules on each project in the Project Defaults Window in Capital Cable Router Admin. The defined rules are available in the Define Rules and Preferences Dialog Box in Capital Cable Router to specify the routing rules on each cable prior to routing the cable.
| Criteria | Behavior |
|---|---|
| Isolated Cable | Cable cannot be routed with any other cables. |
| Barred Cable | Cable (A) and then specified cables (B) that must not share any segment in the cable route (including start / end nodes, where defined). You can choose the following values in the Options column when you add the Barred Cable rule: All Tiers — Cables are barred from sharing the same segment even at different tiers. This is the default behavior if the option value is blank. Same Tier — Cables are barred from sharing the same tier on the segment, but can be routed along different tiers of the same segment. See also Relaxing the Barred Cable Routing Rule. |
| Required Node | Cable must be routed through this node. |
| Prohibited Node | Cable cannot be routed through this node. |
| Named Segment | Cable must be routed through this segment and any other cables already routed must also have this as a Named Segment. |
| Required Segment | Cable must be routed through this segment. |
| Prohibited Segment | Cable cannot be routed through this segment. |
| Required Zone | Cable must be routed through areas within this zone type and no other areas. |
| Prohibited Zone | Cable cannot be routed through any of the areas within this zone type. |
Note
Certain rules work in tandem with other rules and cables, for example, if you deactivate a Barred Cable rule, the named cable associated with the rule will also be deactivated.
Parent Topic:
Routing Rules