Wiring > Prototype Wiring
Usage Example of Storing
a Wiring View
The following is an example of storing a wiring view.
You have the following Capital Systems Integrator design:
Figure 243: Storing Wiring View Example - Capital Systems Integrator Design
You generate a visualized wiring view for signal COND100.
Figure 244: Storing Wiring View Example - Wiring View for COND100
You want to remove device DEV201 from it.
Figure 245: Storing Wiring View Example - Remove Content Dialog Box
The wiring view is regenerated with DEV201 removed.
Figure 246: Storing Wiring View Example - Wiring View with DEV201 Removed
You store this view.
Figure 247: Storing Wiring View Example - Store Action
Figure 248: Storing Wiring View Example - Store View Dialog Box
In the design process, you make changes to the wiring. For example, splicing is disallowed by the use of rules and constraints.
Figure 249: Storing Wiring View Example - Changed Design Constraints
You resynthesize the wiring (selecting the Delete All Wiring option when doing so).
You generate the visualized wiring view for COND100 again, and the wiring has changed accordingly. It has changed from a splice to a multi-term on DEV201.
Figure 250: Storing Wiring View Example - Regenerated Wiring View for COND100
You restore the view that you stored before.
Figure 251: Storing Wiring View Example - Restore View Action
Figure 252: Storing Wiring View Example - Restore View Dialog Box
The following message is displayed.
Figure 253: Storing Wiring View Example - Signal Selection No Longer Exists
The problem is that you removed DEV201 from that stored view and that is where the multi-term now exists.
You need to regenerate the view.
Figure 254: Storing Wiring View Example - Regenerate Action
It regenerates and includes all the devices connected to the signals that you had selected initially.
Figure 255: Storing Wiring View Example - Regenerated Wiring View
From this point, you can use the Build Diagram and Remove Content actions to build a wiring view that includes only connectivity that interests you. You could then store that view.
Note
The stored view continues to exist in the design. If ever you restore it, it uses the latest data to generate a fresh visualization of signal connectivity to those devices that interested you when you stored it. It is not a static image.
Parent Topic:
Prototype Wiring
Capital Systems Integrator User Guide, 2512.2606
Unpublished work. © 2026 Siemens
Source: https://docs.sw.siemens.com/en-US/doc/861057055/202511026.capital_si_user/id1c483abe-ba6f-44f5-b193-c85ea9b45b3f · retrieved 2026-07-18