CapitalKnowledge

Harness Designs > Harness Synchronization > Synchronization Rules

Harness Synchronization Filters

When synchronizing content from the source design, you can filter objects to add specific variants and avoid including all wires, and their related components, into the target design.

You can filter objects based on the following codes:

  • Capital Harness Designer — Option codes

  • Capital Harness Designer Modular — Option or module codes

Filters are only applied to objects that are available for synchronization, as defined by the Change Policies. Filters do not override any Change Policies applied to the synchronization.

The set of option codes that are used as a filter, are stored in different ways:

  • Applicable Options filters are saved in the target design.

  • Configuration filters are saved in the project.

Required Components

Required Components are design content that you require in the target design after synchronization. To enable the filters to populate wires, and their related components during synchronization, the following settings must be specified:

  • Required wires, and their related components, are tagged with option or module codes in the source design.

  • Codes are specified in the Applicable Options or Applicable FM Codes (Capital Harness Designer Modular) in the target design.

  • A Configuration is stored in the project (Configuration filters only).

Tip

Applying filters includes only the required wires and their related components, and avoids manually de-populating objects in the design following synchronization. See “Depopulating Redundant Objects”.

Harness synchronization filter process:

a All content to be synchronized into the new design is assigned to option or module codes in either Capital Logic Designer, Capital Systems Integrator, or Capital Wiring Integrator.
b All content is correctly assigned to harnesses.
c A target harness is defined. The object set associated with the filter is now available.
d All codes used for filtering are entered in the Applicable Options or Applicable FM Codes field in the target design, or in configurations.
e Any Change Policy is applied to the filtered content.
f Filtered content is populated in the target design.

Figure 22: Harness Synchronization Filter Process

Figure 23: Applying Applicable Options Filters (applicable FM Codes - Capital Harness Designer Modular)

Figure 24: Populated Results in the Target Design Following Synchronization

Capital

Logic Designer Designs

Designs created in Capital Logic Designer can be filtered to populate the target design with all wires, and their related components, or specific variants from the source design.

  • None — No filter is applied. The whole content of the source design, assigned to the selected harness, is populated into the target design.

  • Applicable Options — Uses the Applicable Options settings, specified in the target design, to populate content tagged with matching option expressions assigned in the source design. Untagged wires (with no option expressions) also populate the target design.

  • Applicable Functional Module Codes — Uses the Applicable FM Codes settings, specified in the target design, to populate content tagged with matching module codes assigned in the source design (Capital Harness Designer Modular only).

  • Configuration — Opens the Synchronize Filter

  • Configurations Dialog Box to manually select predefined configurations from Capital Project Manager. Untagged wires (with no option code) also populate the target design.

Figure 25: Capital Logic Designer Filter Options

Capital

Systems Integrator and Topology

Designs created in Capital Systems Integrator and Topology can be filtered to populate the target design with all wires, and their related components, or specific variants from the source design.

  • None — No filter is applied. The whole content of the source design, assigned to the selected harness, is populated into the target design.

  • Applicable Options — Uses the Applicable Options settings, specified in the target design, to populate content tagged with matching option expressions assigned in the source design. Untagged wires (with no option expressions) also populate the target design.

  • Applicable Functional Module Codes — Uses the Applicable FM Codes settings, specified in the target design, to populate content tagged with matching module codes assigned in the source design (Capital Harness Designer Modular only).

  • Configuration — Opens the Synchronize Filter

  • Configurations Dialog Box to manually select predefined configurations from Capital Project Manager. Untagged wires (with no option code) also populate the target design.

Applicable Option codes assigned to the target design and used as a filter, can be overwritten during synchronization with Capital Systems Integrator. This is controlled by the Mastered Options setting. See Considerations for Synchronizing Capital Systems Integrator or Topology Designs for using Mastered Options controls.

If the Mastered Options setting is selected, option codes from the Capital Systems Integrator harness replace all existing Applicable Options on the target harness design, and the Applicable Options filter is unavailable in the Filter dropdown list.

Figure 26: Capital Systems Integrator Filter Options with Mastered Options