CapitalKnowledge

Capital Formboard Designer > Automatic Fixture Part Number Selection

Placing Fixtures Automatically

You can select and place fixtures on a diagram automatically. This is achieved using rules and constraints scoped to bundle or component related fixtures.

Restrictions and Limitations

  • If you run automatic fixture placement with individual bundles or components selected, the rules are applied only on the selected objects. Otherwise, fixtures are placed on all valid objects on the diagram.

Prerequisites

  • Valid fixture rules and constraints applicable to the design are defined in the Fixture Constraint Dialog Box.

  • A full scale diagram is open.

  • Valid fixture symbols are available.

Procedure

Select Rules > Place Fixtures from the Automate ribbon. Alternatively, Press Space Bar and enter Place Fixtures.

Results

  • Fixtures with part numbers are automatically placed on the diagram according to the defined rules and constraints. Mandatory additional components defined in the fixture housing definition are selected.

  • Fixtures appear in the relevant Fixtures Folder in the Harness Design Browser.

  • If a fixture already exists at the target location, for example from a previous run of automatic fixture placement, a new fixture is not created. This is the case even if it has a different specification (part number, attributes, or symbol) to the one existing at the target location. You can run Update Fixture Part Numbers and use the Fixture Part Number Validity design rule check (see the Design Rule Checks Applicable to Capital Harness Designer and Capital Harness Designer Modular Designs topic) to ensure the correct fixture part numbers are selected.

  • Bundle fixtures with associated symbols, such as clip holder symbols, are automatically placed by the process at a location based on a combination of: Any offsets you have defined between the symbol graphic and the symbol origin insertion point, as shown in Figure 322. See the Capital Symbol Designer User Guide for details about creating symbols with such offsets. Figure 322: Clip Holder Symbol

Any Nominal Origin offsets you have defined for the symbol decoration in Capital Styling.

Bundle Width extents (including full scale width bundles and non-full scale width bundles).

The following figures show various fixture placement examples using different offsets on full, and non-full scale width bundles.

Figure 323: Full Scale Width Bundle with Styling Offset

Figure 324: Full Scale Width Bundle with no Styling Offset Defined

Figure 325: Non-Full Scale Width Bundle with Styling Offset

Figure 326: Non-Full Scale Width Bundle with no Styling Offset Defined

Parent Topic:

Automatic Fixture Part Number Selection

Related Topics

  • Fixture Placement Constraints

  • Manually Adding a Fixture to a Bundle Segment

  • Manually Adding a Fixture at an Elbow Between Two Segments

  • Manually Adding a Fixture to a Structure Node

  • Add Fixture Help

  • Add Fixture Dialog Box

  • Fixture Position Utility Dialog Box

Capital Harness Designer User Guide, 2512

Unpublished work. © 2025 Siemens

Source: https://docs.sw.siemens.com/en-US/doc/861057055/202410078.capital_hd_user/id1184260c-a3b6-4316-85ff-dcb4484f3ad6 · retrieved 2026-07-18