Pins > Reference Pins
Converting a Reference Instance of a Pin to a Non-Reference Instance
You can convert a reference instance of a pin to a non-reference instance.
Video
This video demonstrates how to convert a reference instance of a pin to a non-reference instance:
Procedure
Select the pin:
Press the space bar and enter Make Non-Reference Pin.
Right-click and select Make Non-Reference Pin.
Note
If the “Disallow pin/port duplication within a design” project preference is selected, you cannot convert a reference instance of a pin to a non-reference instance if a non‑reference instance of the pin already exists, as doing so would create a duplicate pin. See Preventing Pin Duplication Within a Design.
Results
The pin instance is converted to a non-reference instance of the pin.
The red arrow is removed from the pin’s icon in the Design Browser (see Icons in Browsers) and the pin’s representation on the diagram changes from a cross () to a diamond ().
Note
Different cross-reference rules apply to reference and non-reference instances of pins. See Cross-Reference Rules for Pins.
Parent Topic:
Reference Pins
Capital Logic Designer User Guide, 2512
Unpublished work. © 2025 Siemens