Conductors > Nets > Equipotential Nets at a Pin
Setting
the Equipotential Global Attribute for a Shared Pin
You can set the Equipotential Global attribute for a pin on a shared device in Capital Logic Designer.
Procedure
- Select an instance of the pin:Press the space bar and enter Properties.
Right-click and select Properties.
The Properties Dialog Box is displayed.
In the Attributes section of the General tab, enter a string in the Value field for the Equipotential Global attribute. This value will be used as the name of the combined signal in Capital Systems Integrator.Note When the Equipotential Global attribute is set, the Equipotential attribute is unavailable but is not cleared. The Equipotential Global value overrides the Equipotential value when the combined signal is named in Capital Systems Integrator.
Click OK.
Results
When wiring is synthesized in Capital Systems Integrator, the system recognizes the Equipotential Global attribute and creates a combined signal containing the connectivity of all the nets attached to instances of the device pin.
Parent Topic:
Equipotential Nets at a Pin
Related Topics
Equipotential Nets at a Pin
Setting the Equipotential Attribute for a Pin
Capital Logic Designer User Guide, 2512
Unpublished work. © 2025 Siemens