Capital Cable Router Admin > Using Capital Cable Router Admin
Configuring the Project Attributes
You must configure the project attribute default values to ensure that the routing server uses the mandatory settings specified by Siemens.
Procedure
Double-click General administration > Attributes > Attribute Definitions & Permissions.The Attribute Permissions window is displayed.
Click the Enter query conditions button ().
Type 96000502 in the Attribute field, and then click the Execute query button () to open the attribute details.
Double-click the Group code to open the definitions of all the attributes.
Specify the default values using the mandatory values for each of the attributes listed in Table 9.
Click the Save button () to save the values to the routing server.
Click the Close button () to close the Attribute Permissions window.
Examples
| Attribute | Description | Mandatory Value |
|---|---|---|
| 96000502 | Prevent multiple jumps | Y |
| 96000503 | Process virtual segments | Y |
| 96000504 | Secondary cableway types | |
| 96000505 | BNU pre-processing procedure | PKG_CCR_UTILS.PROCESS_DEFERRED |
| 96000506 | Multi-tier separator character | |
| 96000507 | Segregation separator character | , |
| 96000508 | Segregation auto-group prefix | GS |
| 96000509 | Multi-tier auto-group prefix | GM |
| 96000510 | Allow re‑approval after network updates | N |
| 96000511 | Adjust maximum length on re‑approval | N |
| 96000512 | Maximum length % uplift on re‑approval | 0 |
| 96000513 | Allow updates if failed route requests | Y |
| 96000514 | Treat failed auto‑accept as route request failure | Y |
| 96000515 | Check for locks on API update | Y |
Parent Topic:
Using Capital Cable Router Admin
Capital Cable Router User Guide, 2512.2602
Unpublished work. © 2026 Siemens
Source: https://docs.sw.siemens.com/en-US/doc/861057055/202510069.capital_cr_user/id77ae7f6f-6a5e-4cb4-9b04-de0f58428f71 · retrieved 2026-07-18