Wiring > Wire and Multicore Authoring Controls
Wire and Multicore
Authoring Controls Overview
Use the “Only allow Capital Harness Designer-authored wires & multicores to be edited and deleted” project preference to specify that only wires and multicores authored in Capital Harness Designer can be modified.
With the preference set, you are prevented from editing wires and multicores that have been authored outside of Capital Harness Designer. See also “Project Preferences” in the Capital Design Tools Common Functions User Guide.
Note
The restrictions only apply to editing and deleting wires using the Edit Wires Dialog Box, the Edit Multicores Dialog Box, and the Harness Design Browser.
Such wires display with a strike through in the Edit Wires dialog box and Edit Multicores dialog box as shown in Figure 221.
Figure 221: Strike Through Wire Display
Table 17 and Table 18 provide definitions of the authoring tool.
| Wire Creation Method | Defined As |
|---|---|
| Created in Capital Harness Designer. | Capital Harness Designer Authored |
| Created in Capital Harness Designer and then:1. Bridged out from Capital Harness Designer.2. Bridged into Capital Harness Designer. | Capital Harness Designer Authored |
| Wire Creation Method | Defined As |
|---|---|
| Created in Capital Logic Designer or Capital Systems Integrator and then:1. Synchronized from the authoring tool into Capital Harness Designer. | Non-Capital Harness Designer Authored |
| Created in Capital Logic Designer or Capital Systems Integrator and then:1. Bridged out from the authoring tool.2. Bridged into Capital Harness Designer. | Non-Capital Harness Designer Authored |
| Created in Capital Logic Designer or Capital Systems Integrator and then:1. Synchronized from the authoring tool.2. Bridged out from Capital Harness Designer.3. Bridged into Capital Harness Designer. | Non-Capital Harness Designer Authored |
| Bridged from MCAD into Capital Harness Designer, where it is known that the wire was not authored in Capital Harness Designer and is not originating from within a Capital database. | Non-Capital Harness Designer Authored |
| Copied or revised designs: In these cases, the authored status of each wire is the same as the original design, as long as the original design still exists in the database. If the original design no longer exists in the database, all wires will be treated as Non-Capital Harness Designer authored. | Capital Harness Designer / Non-Capital Harness Designer as appropriate |
| Variant wires created using the Variant Position Connectors or Variant Position Splices process: In these cases, if any one variant wire is considered Non-Capital Harness Designer authored, all variants with the same name are also treated as Non-Capital Harness Designer authored. After creating variant wires using one of the variant position processes, you must save the design before editing any of the variant wires. | Capital Harness Designer / Non-Capital Harness Designer as appropriate |
Multicores
Multicores are defined as Capital Harness Designer authored or Non-Capital Harness Designer authored based on the composition of their nested wires.
| Multicore Composition | Defined As |
|---|---|
| All of the multicore nested wires are Capital Harness Designer authored | Capital Harness Designer Authored |
| One or more of the multicore nested wires are non-Capital Harness Designer authored | Non-Capital Harness Designer Authored |
Table 20 details various actions that are available when editing multicores.
| Multicore Edit Action | Available? |
|---|---|
| Add or remove a Capital Harness Designer authored multicore to/from a non-Capital Harness Designer authored multicore. | No |
| Add or remove a Capital Harness Designer authored multicore to/from an Capital Harness Designer authored multicore. | Yes |
| Add or remove a non-Capital Harness Designer authored multicore to/from a Capital Harness Designer authored multicore. | No |
| Add or remove a non-Capital Harness Designer authored multicore to/from a non-Capital Harness Designer authored multicore. | No |
| Add or remove a Capital Harness Designer authored wire to/from a non-Capital Harness Designer authored multicore. | No |
| Add or remove a Capital Harness Designer authored wire to/from a Capital Harness Designer authored multicore. | Yes |
| Add or remove a non-Capital Harness Designer authored wire to/from a Capital Harness Designer authored multicore. | No |
| Add or remove a non-Capital Harness Designer authored wire to/from an non-Capital Harness Designer authored multicore. | No |
Parent Topic:
Wire and Multicore Authoring Controls
Capital Harness Designer User Guide, 2512
Unpublished work. © 2025 Siemens