CapitalKnowledge

Projects and Designs > Designs

Using Design

Abstractions to Control Ribbon Display

The contents of the ribbon are customized based on the design abstraction that is assigned to a Capital Logic Designer design. For example, Logical, Wiring, Fluid, and Smart Flow designs display the ribbon actions which are relevant to their respective type of design abstraction.

Restrictions and Limitations

  • The Fluid design abstraction type is only available if you have set the following parameter to “true” in the clientprops.xml file located in the capital_installation/config folder. Default is “false”. Copy<Enable_fluid_abstraction_type value="true"/>

  • The Single Lines ribbon action is only available if no design abstraction type is selected.

Procedure

  1. Create a design abstraction in Capital Project Manager and specify one of the following Type values:Fluid

Logical

System Block

Wiring

The Type value dictates which version of the ribbon displays for designs assigned with that design abstraction. Figure 2: Editing a Design Abstraction Type See also “Creating Design Abstractions with Default Style Sets” in the Capital Project Manager User Guide.

  1. Assign the design abstraction to your design in the Edit Design dialog box.See also “Editing the Information for a Design” in the Capital Design Tools - Common Functions User Guide. Figure 3: Assigning an Abstraction to a Design

Results

  • When you open diagrams for that design, the ribbon targeted for the design abstraction is displayed.

  • If you are working with the Logical abstraction ribbon, the following actions are removed from the Home tab:

                          Add inline
    

Add plug

						Add ring terminal

Add receptacle

						Add single line

					

					
						Add splice

					

					
						Add wire

The following actions are removed from the Automate tab: Nets to Wires

Generate Harness Connectors Manage Connector

  • If you are working with the Fluid abstraction ribbon (Figure 6), the Home tab is changed: Conductors section removed

Connector types removed

Net is renamed Line

Pin is renamed Ports

  • If you are working with the System Block abstraction ribbon (Figure 7), the Home tab is changed: In the components area, only the add Block and Highway actions are displayed.

  • If you are working with the Smart Flow abstraction ribbon (Figure 8), the Home tab is changed: In the components area, only the following actions are displayed: Step

Transition

Add Link

Add Note

Add Description

Swap Direction

Examples

  • Logical Abstraction

Figure 4: Logical Ribbon

  • Wiring Abstraction

Figure 5: Wiring Ribbon

  • Fluid Abstraction

Figure 6: Fluid Ribbon

  • System Block Abstraction

Figure 7: System Block Ribbon

  • Smart Flow Abstraction

Figure 8: Smart Flow Ribbon

Parent Topic:

Designs

Capital Logic Designer User Guide, 2512

Unpublished work. © 2025 Siemens

Source: https://docs.sw.siemens.com/en-US/doc/861057055/202410078.capital_ld_user/ide730fc2a-08c6-46e9-9c1b-2c9cfff3fcb7 · retrieved 2026-07-18